The required capacity of each door opening shall be sufficient for the occupant load<\/em> thereof and shall provide a minimum clear width of 32 inches (813 mm). Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees (1.57 rad). Where this section requires a minimum clear width of 32 inches (813 mm) and a door opening includes two door leaves without a mullion, one leaf shall provide a clear opening width of 32 inches (813 mm). The maximum width of a swinging door leaf shall be 48 inches (1219 mm) nominal. Means of egress<\/em> doors in a Group I-2 occupancy used for the movement of beds shall provide a clear width not less than 411<\/sup>\/ 2 <\/sub><\/sub> inches (1054 mm). The height of door openings shall be not less than 80 inches (2032 mm).<\/p>- Exceptions:<\/strong>
- The minimum and maximum width shall not apply to door openings that are not part of the required means of egress <\/em>in Group R-2 and R-3 occupancies.<\/li>
- Door openings to resident sleeping units<\/em> in Group I-3 occupancies shall have a clear width of not less than 28 inches (711 mm).<\/li>
- Door openings to storage closets less than 10 square feet (0.93 m2<\/sup>) in area shall not be limited by the minimum width.<\/li>
- Width of door leaves in revolving doors that comply with Section 1010.1.4.1 shall not be limited.<\/li>
- Door openings within a dwelling unit<\/em> or sleeping unit<\/em> shall be not less than 78 inches (1981 mm) in height.<\/li>
- Exterior door openings in dwelling units<\/em> and sleeping units<\/em>, other than the required exit <\/em>door, shall be not less than 76 inches (1930 mm) in height.<\/li>
- In other than Group R-1 occupancies, the minimum widths shall not apply to interior egress doors within a dwelling unit<\/em> or sleeping unit<\/em> that is not required to be an Accessible unit<\/em>, Type A unit <\/em>or Type B unit<\/em>.<\/li>
- Door openings required to be accessible<\/em> within Type B units<\/em> shall have a minimum clear width of 31.75 inches (806 mm).<\/li>
- Doors to walk-in freezers and coolers less than 1,000 square feet (93 m2<\/sup>) in area shall have a maximum width of 60 inches (1524 mm).<\/li>
- In Group R-1 dwelling units<\/em> or sleeping units<\/em> not required to be Accessible units<\/em>, the minimum width shall not apply to doors for showers or saunas.<\/li><\/ol><\/li><\/ul>","new":"
The required capacity of each door opening shall be sufficient for the occupant load<\/span> thereof and shall provide a minimum clear opening width of 32 inches (813 mm). The clear opening width of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees (1.57 rad). Where this section requires a minimum clear opening width of 32 inches (813 mm) and a door opening includes two door leaves without a mullion, one leaf shall provide a minimum clear opening width of 32 inches (813 mm). In Group I-2, doors serving as m<\/em>eans of egress<\/span> doors where used for the movement of beds shall provide a minimum clear opening width of 411<\/sup>\/ 2 <\/sub> inches (1054 mm). The maximum width of a swinging door leaf shall be 48 inches (1219 mm) nominal. The minimum clear opening height of doors shall be 80 inches (2032 mm).<\/p>\n\n- Exceptions:<\/span>\n
\n- In Group R-2 and R-3 dwelling and sleeping units that are not required to be an Accessible unit, Type A unit or Type B unit, the minimum and maximum width shall not apply to door openings that are not part of the required means of egress<\/span>.<\/li>\n
- In Group I-3, door openings to resident sleeping units<\/span> that are not required to be an Accessible unit shall have a minimum clear opening width of 28 inches (711 mm).<\/li>\n
- Door openings to storage closets less than 10 square feet (0.93 m2<\/sup>) in area shall not be limited by the minimum clear opening width.<\/li>\n
- The width of door leaves in revolving doors that comply with Section 1010.1.4.1 shall not be limited.<\/li>\n
- Door openings within a dwelling unit<\/span> or sleeping unit<\/span> shall have a minimum clear opening height than 78 inches (1981 mm) in height.<\/li>\n
- In dwelling and sleeping units that are not required to be Accessible, Type A or Type B units, exterior door openings, other than the required exit <\/span>door, shall have a minimum clear opening height of 76 inches (1930 mm) in height.<\/li>\n
- Groups I-1, R-2, R-3 and R-4 occupancies, in dwelling and sleeping units that are not required to be Accessible, Type A or Type B units, the minimum clear opening widths shall not apply to interior egress doors.<\/li>\n
- Door openings within Type B units<\/span> intended for user passage shall have a minimum clear opening width of 31.75 inches (806 mm).<\/li>\n
- Doors to walk-in freezers and coolers less than 1,000 square feet (93 m2<\/sup>) in area shall have a maximum width of 60 inches (1524 mm) nominal.<\/li>\n
- The minimum clear opening width shall not apply to doors for non-accessible shower or sauna compartments.<\/li>\n
- The minimum clear opening width shall not apply to the doors for non-accessible toilet stalls.<\/li>\n<\/ol>\n<\/li>\n<\/ul>"},{"name":"test","old":"
The required capacity of each door opening shall be sufficient for the occupant load<\/em> thereof and shall provide a minimum clear width of 32 inches (813 mm). Clear openings of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees (1.57 rad). Where this section requires a minimum clear width of 32 inches (813 mm) and a door opening includes two door leaves without a mullion, one leaf shall provide a clear opening width of 32 inches (813 mm). The maximum width of a swinging door leaf shall be 48 inches (1219 mm) nominal. Means of egress<\/em> doors in a Group I-2 occupancy used for the movement of beds shall provide a clear width not less than 411<\/sup>\/ 2 <\/sub><\/sub> inches (1054 mm). The height of door openings shall be not less than 80 inches (2032 mm).<\/p>","new":"The required capacity of each door opening shall be sufficient for the occupant load<\/span> thereof and shall provide a minimum clear opening width of 32 inches (813 mm). The clear opening width of doorways with swinging doors shall be measured between the face of the door and the stop, with the door open 90 degrees (1.57 rad). Where this section requires a minimum clear opening width of 32 inches (813 mm) and a door opening includes two door leaves without a mullion, one leaf shall provide a minimum clear opening width of 32 inches (813 mm). In Group I-2, doors serving as m<\/em>eans of egress<\/span> doors where used for the movement of beds shall provide a minimum clear opening width of 411<\/sup>\/ 2 <\/sub> inches (1054 mm). The maximum width of a swinging door leaf shall be 48 inches (1219 mm) nominal. The minimum clear opening height of doors shall be 80 inches (2032 mm).<\/p>\n\n- Exceptions:<\/span>\n
\n- In Group R-2 and R-3 dwelling and sleeping units that are not required to be an Accessible unit, Type A unit or Type B unit, the minimum and maximum width shall not apply to door openings that are not part of the required means of egress<\/span>.<\/li>\n
- In Group I-3, door openings to resident sleeping units<\/span> that are not required to be an Accessible unit shall have a minimum clear opening width of 28 inches (711 mm).<\/li>\n
- Door openings to storage closets less than 10 square feet (0.93 m2<\/sup>) in area shall not be limited by the minimum clear opening width.<\/li>\n
- The width of door leaves in revolving doors that comply with Section 1010.1.4.1 shall not be limited.<\/li>\n
- Door openings within a dwelling unit<\/span> or sleeping unit<\/span> shall have a minimum clear opening height than 78 inches (1981 mm) in height.<\/li>\n
- In dwelling and sleeping units that are not required to be Accessible, Type A or Type B units, exterior door openings, other than the required exit <\/span>door, shall have a minimum clear opening height of 76 inches (1930 mm) in height.<\/li>\n
- Groups I-1, R-2, R-3 and R-4 occupancies, in dwelling and sleeping units that are not required to be Accessible, Type A or Type B units, the minimum clear opening widths shall not apply to interior egress doors.<\/li>\n
- Door openings within Type B units<\/span> intended for user passage shall have a minimum clear opening width of 31.75 inches (806 mm).<\/li>\n
- Doors to walk-in freezers and coolers less than 1,000 square feet (93 m2<\/sup>) in area shall have a maximum width of 60 inches (1524 mm) nominal.<\/li>\n
- The minimum clear opening width shall not apply to doors for non-accessible shower or sauna compartments.<\/li>\n
- The minimum clear opening width shall not apply to the doors for non-accessible toilet stalls.<\/li>\n<\/ol>\n<\/li>\n<\/ul>"},{"name":"Last and First","old":"
\n- \nEtiam feugiat lorem non metus. Nullam accumsan lorem in dui.\n<\/li>\n\n
- \nPraesent ac sem eget est egestas volutpat. Nulla neque dolor, sagittis eget, iaculis quis, molestie non, velit. Maecenas tempus, tellus eget condimentum rhoncus, sem quam semper libero, sit amet adipiscing sem neque sed ipsum. Integer ante arcu, accumsan a, consectetuer eget, posuere ut, mauris. Aenean massa.\n<\/li>\n\n
- \n Vestibulum suscipit nulla quis orci. Integer ante arcu, accumsan a, consectetuer eget, posuere ut, mauris. Class aptent taciti sociosqu ad litora torquent per conubia nostra, per inceptos hymenaeos.\n<\/li>\n\n
- \nSuspendisse non nisl sit amet velit hendrerit rutrum. Aenean massa. Curabitur ullamcorper ultricies nisi. Praesent vestibulum dapibus nibh. In dui magna, posuere eget, vestibulum et, tempor auctor, justo.\n<\/li>\n<\/ol>","new":"
\n- \nSuspendisse non nisl sit amet velit hendrerit rutrum. Aenean massa. Curabitur ullamcorper ultricies nisi. Praesent vestibulum dapibus nibh. In dui magna, posuere eget, vestibulum et, tempor auctor, justo.\n<\/li>\n\n
- \nDonec pede justo, fringilla vel, aliquet nec, vulputate eget, arcu.\n<\/li>\n\n
- \nDuis lobortis massa imperdiet quam. Donec sodales sagittis magna. Nam ipsum risus, rutrum vitae, vestibulum eu, molestie vel, lacus. Suspendisse eu ligula. Morbi nec metus.\n<\/li>\n<\/ol>"},{"name":"First and Last","old":"
\n- \nSuspendisse non nisl sit amet velit hendrerit rutrum. Aenean massa. Curabitur ullamcorper ultricies nisi. Praesent vestibulum dapibus nibh. In dui magna, posuere eget, vestibulum et, tempor auctor, justo.\n<\/li>\n\n
- \nDonec pede justo, fringilla vel, aliquet nec, vulputate eget, arcu.\n<\/li>\n\n
- \nDuis lobortis massa imperdiet quam. Donec sodales sagittis magna. Nam ipsum risus, rutrum vitae, vestibulum eu, molestie vel, lacus. Suspendisse eu ligula. Morbi nec metus.\n<\/li>\n<\/ol>","new":"
\n- \nEtiam feugiat lorem non metus. Nullam accumsan lorem in dui.\n<\/li>\n\n
- \nPraesent ac sem eget est egestas volutpat. Nulla neque dolor, sagittis eget, iaculis quis, molestie non, velit. Maecenas tempus, tellus eget condimentum rhoncus, sem quam semper libero, sit amet adipiscing sem neque sed ipsum. Integer ante arcu, accumsan a, consectetuer eget, posuere ut, mauris. Aenean massa.\n<\/li>\n\n
- \n Vestibulum suscipit nulla quis orci. Integer ante arcu, accumsan a, consectetuer eget, posuere ut, mauris. Class aptent taciti sociosqu ad litora torquent per conubia nostra, per inceptos hymenaeos.\n<\/li>\n\n
- \nSuspendisse non nisl sit amet velit hendrerit rutrum. Aenean massa. Curabitur ullamcorper ultricies nisi. Praesent vestibulum dapibus nibh. In dui magna, posuere eget, vestibulum et, tempor auctor, justo.\n<\/li>\n<\/ol>"},{"name":"Remove first, add last","old":"
\n- \nSuspendisse non nisl sit amet velit hendrerit rutrum. Aenean massa. Curabitur ullamcorper ultricies nisi. Praesent vestibulum dapibus nibh. In dui magna, posuere eget, vestibulum et, tempor auctor, justo.\n<\/li>\n\n
- \nDonec pede justo, fringilla vel, aliquet nec, vulputate eget, arcu.\n<\/li>\n\n
- \nDuis lobortis massa imperdiet quam. Donec sodales sagittis magna. Nam ipsum risus, rutrum vitae, vestibulum eu, molestie vel, lacus. Suspendisse eu ligula. Morbi nec metus.\n<\/li>\n<\/ol>","new":"
\n- \nDonec pede justo, fringilla vel, aliquet nec, vulputate eget, arcu.\n<\/li>\n\n
- \nPraesent ac sem eget est egestas volutpat. Nulla neque dolor, sagittis eget, iaculis quis, molestie non, velit. Maecenas tempus, tellus eget condimentum rhoncus, sem quam semper libero, sit amet adipiscing sem neque sed ipsum. Integer ante arcu, accumsan a, consectetuer eget, posuere ut, mauris. Aenean massa.\n<\/li>\n\n
- \n Vestibulum suscipit nulla quis orci. Integer ante arcu, accumsan a, consectetuer eget, posuere ut, mauris. Class aptent taciti sociosqu ad litora torquent per conubia nostra, per inceptos hymenaeos.\n<\/li>\n\n
- \nSuspendisse non nisl sit amet velit hendrerit rutrum. Aenean massa. Curabitur ullamcorper ultricies nisi. Praesent vestibulum dapibus nibh. In dui magna, posuere eget, vestibulum et, tempor auctor, justo.\n<\/li>\n<\/ol>"},{"name":"1006.3.1 Adjacent story","old":"
The path of egress travel to an exit shall not pass through more than one adjacent story.<\/div>\n
\u00a0<\/div>\n
Exception:<\/strong> \u00a0The path of egress travel to an exit shall be permitted to pass through more than one adjacent story in any of the following:<\/div>\n- In Group R-1, R-2 or R-3 occupancies, exit access stairways and ramps connecting four stories or less serving and contained within an individual dwelling unit or sleeping unit or live\/work unit.<\/li>\n
- Exit access stairways serving and contained within a Group R-3 congregate residence or a Group R-4 facility.<\/li>\n
- Exit access stairways and ramps in open parking garages that serve only the parking garage.<\/li>\n
- Exit access stairways and ramps serving open-air assembly seating complying with the exit access travel distance requirements of Section 1029.7.<\/li>\n
- Exit access stairways and ramps between the balcony, gallery or press box and the main assembly floor in occupancies such as theaters, places of religious worship, auditoriums and sports facilities.<\/li>\n<\/ol>
\u00a0<\/div>","new":"
The path of egress travel to an exit shall not pass through more than one adjacent story.<\/div>\n
\u00a0<\/div>\n
Exception:<\/strong> \u00a0The path of egress travel to an exit shall be permitted to pass through more than one adjacent story in any of the following:<\/div>\n- In Group R-1, R-2 or R-3 occupancies, exit access stairways and ramps connecting four stories or less serving and contained within an individual dwelling unit or sleeping unit or live\/work unit.<\/li>\n
- Exit access stairways serving and contained within a Group R-3 congregate residence or a Group R-4 facility.<\/li>\n
- Exit access stairways and ramps in open parking garages that serve only the parking garage.<\/li>\n
- Exit access stairways and ramps in buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, where the area of the vertical opening between stories does not exceed twice the horizontal projected area of the stairway or ramp and the opening is protected by a draft curtain and closely spaced sprinklers in accordance with NFPA 13. \u00a0In other than Group B and M occupancies, this\u00a0provision is limited to openings that do not connect more than four stories.<\/li>\n
- Exit access stairways and ramps within an atrium complying with the provisions of Section 404.<\/li>\n
- Exit access stairways and ramps serving open-air assembly seating complying with the exit access travel distance requirements of Section 1029.7.<\/li>\n
- Exit access stairways and ramps between the balcony, gallery or press box and the main assembly floor in occupancies such as theaters, places of religious worship, auditoriums and sports facilities.<\/li>\n<\/ol>
\u00a0<\/div>","legislativeOverride":"
\n
\n
1006.3.1 Adjacent story.<\/strong> \nThe path of egress travel to an exit shall not pass through more than one adjacent story.<\/div>\n
<\/div>\n
Exception:<\/strong> The path of egress travel to an exit shall be permitted to pass through more than one adjacent story in any of the following:<\/div>\n\n- In Group R-1, R-2 or R-3 occupancies, exit access stairways and ramps connecting four stories or less serving and contained within an individual dwelling unit or sleeping unit or live\/work unit.<\/li>\n
- Exit access stairways serving and contained within a Group R-3 congregate residence or a Group R-4 facility.<\/li>\n
- Exit access stairways and ramps in open parking garages that serve only the parking garage.<\/li>\n
- Exit access stairways and ramps<\/span> in buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, where the area of the vertical opening between stories does not exceed twice the horizontal projected area of the stairway or ramp and the opening is protected by a draft curtain and closely spaced sprinklers in accordance with NFPA 13. In other than Group B and M occupancies, this provision is limited to openings that do not connect more than four stories.<\/ins><\/li>\n <\/ins>\n
- Exit access stairways and ramps within an atrium complying with the provisions of Section 404.<\/ins><\/li>\n <\/ins>\n
- <\/ins>Exit access stairways and ramps serving open-air assembly seating complying with the exit access travel distance requirements of Section 1029.7.<\/li>\n
- Exit access stairways and ramps between the balcony, gallery or press box and the main assembly floor in occupancies such as theaters, places of religious worship, auditoriums and sports facilities.<\/li>\n<\/ol>\n
<\/div>\n<\/div>\n<\/div>\n<\/div>"},{"name":"1030.1 General.","old":"
In addition to the means of egress<\/em> required by this chapter, provisions shall be made for emergency escape and rescue openings<\/em> in Group R occupancies. Basements<\/em> and sleeping rooms below the fourth story above grade plane<\/em> shall have at least one exterior emergency escape and rescue opening<\/em> in accordance with this section. Where basements<\/em> contain one or more sleeping rooms, emergency escape and rescue openings<\/em> shall be required in each sleeping room, but shall not be required in adjoining areas of the basement<\/em>. Such openings shall open directly into a public way<\/em> or to a yard <\/em>or court<\/em> that opens to a public way<\/em>.<\/p>\n- Exceptions:<\/strong>
- Groups R-1 and R-2 occupancies are not required to provide emergency and escape openings where they comply with all of the following:<\/em>
- Each story has access to two or more means of egress.
<\/em><\/li>\n- The building is constructed of Type I, Type II, Type IIIA or Type IV construction.<\/em><\/li>\n
- The building is equipped throughout with an approved automatic sprinkler system in accordance with Sections 903.3.1.1 or 903.3.3.2.<\/em><\/li>\n<\/ol><\/li>\n
- The emergency escape and rescue opening is permitted to open onto a balcony within an atrium in accordance with the requirements of Section 404, provided the balcony provides access to an exit and the dwelling unit or sleeping unit has a means of egress that is not open to the atrium.<\/em><\/li>\n
- Basements<\/em> with a ceiling height of less than 80 inches (2032 mm) shall not be required to have emergency escape and rescue openings<\/em>.<\/li>\n
- Emergency escape and rescue openings<\/em> are not required from basements<\/em> or sleeping rooms that have an exit<\/em> door or exit access<\/em> door that opens directly into a public way<\/em> or to a yard<\/em>, court<\/em> or exterior exit balcony that opens to a public way<\/em>.<\/li>\n
- Basements<\/em> without habitable spaces<\/em> and having not more than 200 square feet (18.6 m2<\/sup>) in floor area shall not be required to have emergency escape and rescue openings<\/em>.<\/li>\n<\/ol><\/li>\n<\/ul>","new":"
In addition to the means of egress<\/em> required by this chapter, emergency escape and rescue openings <\/em>shall be provided in the following occupancies:<\/p>\n1. Group R-1 and R-2 occupancies.<\/div>\n
2. Group R-1 and R-2 occupancies located on stories with one exit or access to one exit where permitted by Tables 1006.3.2(1) and 1006.3.2(2).\u00a0<\/div>\n
3. Group R-3 occupancies.<\/div>\n
Basements<\/em> and sleeping rooms below the fourth story above grade plane<\/em> shall have at least one exterior emergency escape and rescue opening<\/em> in accordance with this section. Where basements<\/em> contain one or more sleeping rooms, emergency escape and rescue openings<\/em> shall be required in each sleeping room, but shall not be required in adjoining areas of the basement<\/em>. Such openings shall open directly into a public way<\/em> or to a yard <\/em>or court<\/em> that opens to a public way<\/em>.<\/p>\n- Exceptions:<\/strong>
- Emergency escape and rescue opening<\/em> are not required from Group R-1 and R-2 occupancies where each story has access to at least two exits or access to exits and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.<\/li>\n
- Basements<\/em> with a ceiling height of less than 80 inches (2032 mm) shall not be required to have emergency escape and rescue openings<\/em>.<\/li>\n
- Emergency escape and rescue openings<\/em> are not required from basements<\/em> or sleeping rooms that have an exit<\/em> door or exit access<\/em> door that opens directly into a public way<\/em> or to a yard<\/em>, court<\/em> or exterior exit balcony that opens to a public way<\/em>.<\/li>\n
- Basements<\/em> without habitable spaces<\/em> and having not more than 200 square feet (18.6 m2<\/sup>) in floor area shall not be required to have emergency escape and rescue openings<\/em>.<\/li>\n<\/ol><\/li>\n<\/ul>","legislativeOverride":"
\n
\n
1030.1 General.<\/strong> In addition to the means of egress<\/em> required by this chapter, provisions shall be made for <\/del>emergency escape and rescue openings <\/ins><\/em>shall be provided<\/ins> in the following occupancies:<\/ins> <\/ins>\n1. <\/ins>Group R<\/del> R-1 and R-2<\/ins> occupancies. <\/del><\/div>\n <\/ins>\n2. Group R-1 and R-2 occupancies located on stories with one exit or access to one exit where permitted by Tables 1006.3.2(1) and 1006.3.2(2). <\/ins><\/div>\n <\/ins>\n3. Group R-3 occupancies.<\/ins><\/div>\n <\/ins>\n
Basements<\/em> and sleeping rooms below the fourth story above grade plane<\/em> shall have at least one exterior